DC/DC Converter
THB 10 Series, 10 Watt
•
Supplementary and reinforced
insulation
•
I/O isolation 4000 VACrms rated for 300
Vrms working voltage
•
2 x MOOP Medical safety according to
AAMI/ANSI ES 60601-1:2005(R) and
IEC/EN 60601-1 3rd edition
•
•
•
Industrial safety to UL/IEC/EN 62368-1
•
•
•
•
Input filter meets EN55022, class A
Wide 2:1 input voltage ranges
Extended operating temperature range
–40°C to 75°C max.
Continuous short-circuit protection
ES 60601-1 IEC 60601-1
UL 62368-1 IEC 62368-1
The THB 10 series is a range of high performance DC/DC converter modules
with double reinforced insulation system. It complies to latest medical safety
standard IEC 60950-1 3rd edition for MOOP (Means of Operator Protection).
The product comes in a 2”x1” industry standard package. All 12 models features wide 2:1 input voltage range and fully regulated output voltage. The converters offer an economical solution for demanding applications in industrial
and medical instrumentation.
High reliability
3-year product warranty
Models
Order Code
Input Voltage
Range
THB 10-1211
THB 10-1212
THB 10-1222
THB 10-1223
THB 10-2411
THB 10-2412
THB 10-2422
THB 10-2423
THB 10-4811
THB 10-4812
THB 10-4822
THB 10-4823
www.tracopower.com
9 - 18 VDC
(12 VDC nom.)
18 - 36 VDC
(24 VDC nom.)
36 - 75 VDC
(48 VDC nom.)
Output 1
Output 2
Vnom
Imax
5.1 VDC
12 VDC
+12 VDC
+15 VDC
5.1 VDC
12 VDC
+12 VDC
+15 VDC
5.1 VDC
12 VDC
+12 VDC
+15 VDC
1'600 mA
835 mA
417 mA
333 mA
2'000 mA
835 mA
417 mA
333 mA
2'000 mA
835 mA
417 mA
333 mA
September 20, 2023
Vnom
Efficiency
Imax
–12 VDC
–15 VDC
417 mA
333 mA
–12 VDC
–15 VDC
417 mA
333 mA
–12 VDC
–15 VDC
417 mA
333 mA
typ.
75 %
80 %
80 %
81 %
76 %
81 %
81 %
82 %
76 %
81 %
81 %
82 %
Page 1 / 4
THB 10 Series, 10 Watt
Input Specifications
Input Current
- At no load
12 Vin models:
24 Vin models:
48 Vin models:
12 Vin models:
- At full load
24 Vin models:
48 Vin models:
Surge Voltage
12 Vin models:
24 Vin models:
48 Vin models:
12 Vin models:
24 Vin models:
48 Vin models:
12 Vin models:
24 Vin models:
48 Vin models:
12 Vin models:
24 Vin models:
48 Vin models:
12 Vin models:
24 Vin models:
48 Vin models:
Start-up Voltage
Under Voltage Lockout
Reflected Ripple Current
Recommended Input Fuse
Input Filter
Short Circuit Input Power
30 mA typ.
20 mA typ.
10 mA typ.
905 mA typ. (5.1 Vout model)
1'040 mA typ. (12 Vout model)
1'040 mA typ. (12 / -12 Vout model)
1'040 mA typ. (15 / -15 Vout model)
560 mA typ. (5.1 Vout model)
515 mA typ. (12 Vout model)
515 mA typ. (12 / -12 Vout model)
515 mA typ. (15 / -15 Vout model)
280 mA typ. (5.1 Vout model)
255 mA typ. (12 Vout model)
255 mA typ. (12 / -12 Vout model)
255 mA typ. (15 / -15 Vout model)
25 VDC max. (1 s max.)
50 VDC max. (1 s max.)
100 VDC max. (1 s max.)
7 VDC min. / 8 VDC typ. / 9 VDC max.
13 VDC min. / 15 VDC typ. / 18 VDC max.
30 VDC min. / 33 VDC typ. / 36 VDC max.
8.5 VDC max.
16 VDC max.
34 VDC max.
100 mA typ.
50 mA typ.
25 mA typ.
3'000 mA (slow blow)
1'500 mA (slow blow)
750 mA (slow blow)
(The need of an external fuse has to be assessed
in the final application.)
Internal Pi-Type
3 W max.
Output Specifications
Voltage Set Accuracy
Regulation
- Input Variation (Vmin - Vmax)
- Load Variation (15 - 100%)
Ripple and Noise
(20 MHz Bandwidth)
- single output
- dual output
Capacitive Load
- single output
- dual output
single output models:
dual output models:
single output models:
dual output models:
5.1 Vout models:
12 Vout models:
12 / -12 Vout models:
15 / -15 Vout models:
5.1 Vout models:
12 Vout models:
12 / -12 Vout models:
15 / -15 Vout models:
Minimum Load
Temperature Coefficient
Short Circuit Protection
Output Current Limitation
±1% max.
0.5% max.
0.5% max.
1% max.
1% max. (Output 1)
1% max. (Output 2)
100 mVp-p max.
150 mVp-p max.
150 / 150 mVp-p max.
150 / 150 mVp-p max.
1'000 µF max.
470 µF max.
220 / 220 µF max.
220 / 220 µF max.
Not required
±0.05 %/K max.
Continuous, Automatic recovery
120% min. of Iout max.
150% typ. of Iout max.
All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.
www.tracopower.com
September 20, 2023
Page 2 / 4
THB 10 Series, 10 Watt
Transient Response
3% typ. / 5% max. (75% to 100% Load Step)
300 µs typ. / 600 µs max. (75% to 100% Load
Step)
- Response Deviation
- Response Time
Safety Specifications
Safety Standards
CSA-C22.2, No. 60950-1
EN 60950-1
EN 62368-1
IEC 60950-1
IEC 62368-1
UL 60950-1
UL 62368-1
EN 60601-1
IEC 60601-1
ANSI/AAMI ES 60601-1
CSA-C22.2, No 60601-1
2 x MOOP (Means Of Operator Protection)
MOPP (Means Of Patient Protection)
www.tracopower.com/overview/thb10
PD 3
Not mains connected
- IT / Multimedia Equipment
- Medical Equipment
- Certification Documents
Pollution Degree
Over Voltage Category
EMC Specifications
EMI Emissions
- Conducted Emissions
- Radiated Emissions
External filter proposal:
EMS Immunity
- Electrostatic Discharge
Air:
Contact:
- RF Electromagnetic Field
- EFT (Burst) / Surge
Ext. input component:
- Conducted RF Disturbances
- PF Magnetic Field
Continuous:
EN 60601-1-2 edition 4 (Medical Devices)
EN 55011 class A (with external filter)
EN 55011 class A (with external filter)
www.tracopower.com/overview/thb10
EN 60601-1-2 edition 4 (Medical Devices)
EN 61000-4-2, ±15 kV, perf. criteria A
EN 61000-4-2, ±8 kV, perf. criteria A
EN 61000-4-3, 10 V/m, perf. criteria A
EN 61000-4-4, ±2 kV, perf. criteria A
EN 61000-4-5, ±1 kV, perf. criteria A
330 μF / 35 V (12 Vin models)
330 μF / 50 V (24 Vin models)
330 μF / 100 V (48 Vin models)
EN 61000-4-6, 10 Vrms, perf. criteria A
EN 61000-4-8, 30 A/m, perf. criteria A
General Specifications
Relative Humidity
Temperature Ranges
Power Derating
- Operating Temperature
- Case Temperature
- Storage Temperature
- High Temperature
Cooling System
Altitude During Operation
Switching Frequency
Insulation System
Working Voltage (rated)
Isolation Test Voltage
Isolation Resistance
- Input to Output, 60 s
- Input to Output, 500 VDC
95% max. (non condensing)
–40°C to +75°C
+95°C max.
–50°C to +125°C
2.85 %/K above 60°C
See application note: www.tracopower.com/overview/thb10
Natural convection (20 LFM)
5'000 m max.
120 - 180 kHz (PWM)
150 kHz typ. (PWM)
Reinforced Insulation
300 VAC (acc. to IEC/EN 60601-1)
1000 VAC (acc. to IEC/EN 62368-1, 60950-1)
4'200 VAC
10'000 MΩ min.
All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.
www.tracopower.com
September 20, 2023
Page 3 / 4
THB 10 Series, 10 Watt
Isolation Capacitance
- Input to Output, 100 kHz, 1 V
Leakage Current
Reliability
Washing Process
- Earth Leakage Current
- Calculated MTBF
Housing Material
Potting Material
Pin Material
Pin Foundation Plating
Pin Surface Plating
Housing Type
Mounting Type
Connection Type
Footprint Type
Soldering Profile
Weight
Environmental Compliance - REACH Declaration
- RoHS Declaration
- SCIP Reference Number
60 pF typ.
80 pF max.
10 µA max.
1'000'000 h (MIL-HDBK-217F, ground benign)
According to Cleaning Guideline
www.tracopower.com/info/cleaning.pdf
Non-conductive Plastic (UL 94 V-0 rated)
Silicone (UL 94 V-0 rated)
Copper Alloy (C6801)
Nickel (2.5 µm min.)
Gold (75 - 125 nm), glossy
Plastic Case
PCB Mount
THD (Through-Hole Device)
2" x 1"
Lead-Free Wave Soldering
260°C / 10 s max.
24.5 g
www.tracopower.com/info/reach-declaration.pdf
REACH SVHC list compliant
REACH Annex XVII compliant
www.tracopower.com/info/rohs-declaration.pdf
Exemptions: 7a
(RoHS exemptions refer to the component
concentration only, not to the overall
concentration in the product (O5A rule).)
6643ce60-44b4-4d3b-b3d0-21abce17c45b
Supporting Documents
Overview Link (for additional Documents)
www.tracopower.com/overview/thb10
Outline Dimensions
5.08
Pinout
(0.2
2.54
(0.1)
(2.0)
50.8
(1.8)
45.72
2
4
(0.1
2.54
Dual
1
+Vin (Vcc)
+Vin (Vcc)
2
–Vin (GND)
–Vin (GND)
3
+Vout
+Vout
4
No pin
Common
5
–Vout
–Vout
3
10.16
5.08
(0.4)
(0.2
(0.47)
Single
Bottom view
5
12.0
1
Pin
20.32
(0.8)
25.4
(1.0)
Dimensions in mm (inch)
Tolerances: x.x ±0.5 (±0.02)
x.xx ±0.25 (±0.01)
Pin Ø 1.0 ±0.05 (0.04 ±0.002)
Pin pitch tolerances ±0.13 (±0.005)
© Copyright 2023 Traco Electronic AG
Specifications can be changed without notice.
www.tracopower.com
Rev. September 20, 2023
Page 4 / 4
很抱歉,暂时无法提供与“THB 10-1212”相匹配的价格&库存,您可以联系我们找货